BQTBR - AZH 140 DC-1

  • MSDS: BQTBR
  • Manufacturer: BST SYSTEM INC
  • Product Name: AZH 140 DC-1
  • National Stock Number: 6140-00N016184
Product Identification

Product ID:AZH 140 DC-1
MSDS Date:01/05/1990
FSC:6140
NIIN:00N016184
MSDS Number: BQTBR

Responsible Party
BST SYSTEM INC
RTE 14A PLAINFIELD PIKE
PLAIFIELD, CT 06374-9607
US

Emergency Phone: 203-564-4078

Info Phone: 203-564-4078

Cage: 62399

Contractor
BST SYSTEM INC
PLAIFIELD, CT 06374-9607 US

Telephone: 203-564-4078

Cage: 62399

Ingredients

SILVER

CAS: 7440-22-4

RTECS: VW3500000

OSHA PEL 0.01 MG/M3

ACGIH TLV: 0.1 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ZINC OXIDE

CAS: 1314-13-2

RTECS: ZH4810000

OSHA PEL 15MG/M3 TDUST/5 FUME

ACGIH TLV: 10MG/M3 TDUST; 9293


MERCURY (II) OXIDE; (MERCURIC OXIDE)

CAS: 21908-53-2

RTECS: OW8570000

OSHA PEL 0.05 MG/M3 (MFR)

ACGIH TLV: 10 MG/M3 (MFR)


POLYSULFONE

CAS: 25154-01-2


POTASSIUM HYDROXIDE

CAS: 1310-58-3

RTECS: TT2100000

OSHA PEL 2 MG/M3, C

ACGIH TLV: 2 MG/M3, C

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: ACTIVATED BATTERY MAY BE A FIRE
HAZARD IF INADVERTANTLY EXTERNALLY SHORTED; DIRECT CONTACT WITH KOH
MAY BURN TISSUE; FIRE MAY LIBERATE MERCURY FUMES. CHRONIC: MERCURY
COMPOUNDS APPEAR ON THE NA VY LISTING OF OCCUPATIONAL CHEMICAL
REPRODUCTIVE HAZARDS. SEEK CONSULTATION FROM APPROPRIATE HEALTH
(SYMPT OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:KOH-CONTACT W/SKIN CAUSES BURNS, INHALATION OF
MIST MAY DAMAGE RESPIRATORY TRACT, INGESTION CAUSES THROAT AND
GASTRO-RESPIRATORY BURNS. HEALTH HAZARDS: PROFESSIONALS CONCERNING
THE LATEST HAZARD LIST INFORMATION AND SAFE HANDLING AND EXPOSURE
INFORMATION .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE FROM EXPOSURE AND GET MEDICAL HELP. SKIN:
REMOVE CONTAMINATED CLOTHING AND WASH WITH WATER. EYES: FLUSH WITH
WATER FOR AT LEAST 15 MINUTES AND GET MEDICAL HELP. INGEST: DRINK
WATER DON'T INDUCE VOMIT AND GET MEDICAL HELP.

Fire Fighting

Extinguishing Media:WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:FIRE MAY LIBERATE TOX MERCURY FUMES AS
WELL AS HAZ FLUORINE CMPDS; INCOMPLETE BURNING OF POLYSURF ONE MAY
REL CARBON MONOXIDE & CARBON DIXOIDE; (SUPP DATA)

Accidental Release

Spill Release Procedures:FOR KOH SPILL-WEAR PROTECTIVE CLOTHING
INCLUDING GLOVES, GOGGLES; AVOID CONTACT WITH SKIN; CONTAIN SPILL
AND NEUTRALIZE WITH WEAK ACID (VINEGAR, BORIC ACID) AND FLUSH WITH
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DRY BATTERIES TO BE STORED AT TEMPS
BETWEEN 0-40F(OPTIMIM).
Other Precautions:WET BATTERIES NOT REQUIRED FOR 30 DAYS OR LONGER
SHOULD BE DISCHARGED AS PER MFR'S OPERATING PROCEDURES AND STORED
AT TEMPS BETWEEN 0-40F.

Exposure Controls

Respiratory Protection:NONE REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:RUBBER/PLASTIC.
Eye Protection:CHEMICAL WORKERS GOGGLES AND (SUP DATA)
Other Protective Equipment:LIQUID RESISTANT APRONS; SAFETY EYE
WASH/SHOWER STATIONS.
Work Hygienic Practices:AVOID DIRECT SKIN CONTACT WITH KOH; TO REDUCE
ELECTROCUTION RISK; ALL ASSOCIATED TOOLS SHOULD BE INSULATED.
Supplemental Safety and Health
EXPLO HAZ: CONT OF KOH WITH METALS CAN RELEASE HYDROGEN GAS. EYE
PROTECTION: FULL LENGTH FACESHIELD .

Chemical Properties

HCC:N1
Appearance and Odor:CELL-RECTANGULAR CUBE CLEAR AMBER COLOR WITH
MULTIPLE ELECTRODES VISIBLE

Stability

Stability Indicator/Materials to Avoid:YES
HYDROGEN PEROXIDE, AMINES, REDUCING AGENTS, MOLTEN ALKALI METALS,
ALUMINUM & TIN (KOH ONLY).
Stability Condition to Avoid:AVOID STORAGE TEMPERATURES >70F.
Hazardous Decomposition Products:AT TEMPS HIGHER THAN 962C, AG*2O FUME
MAYBE EVOLED; KOH METALS MAY LIBERATE H*2 GAS.
Conditions to Avoid Polymerization:HYDROGEN FLUODIE MAY BE FORMED WHEN
TEFLON BURNS.

Disposal

Waste Disposal Methods:SPENT(USED) BATTERIES SHOULD BE COLLECTED FOR
PRECIOUS METALS RECLAMATIONS. DISPOSE OF I/A/W FEDERAL, STATE AND
LOCAL REGULATIONSS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.